Operator Panel Reference
43
I/O Config.
Parameter Values Description
Baud Rate 300, 600, 1200,
2400, 4800,
9600, 19200,
38400, or
57600
Selects the serial port baud
rate
Flow Control Hardware,
Xon/Xoff
Normal, or
Xon/Xoff
Robust
Selects the flow control
interaction with the host
computer
RTS Polarity Online = High
or
Online = Low
Selects the RTS signal level
for its asserted state
DTR Polarity Ready = High
or
Ready = Low
Selects the DTR signal level
for its asserted state
Parity None, Even or
Odd
Selects the parity for serial
communications
Data Bits 8 or 7 Selects the data word size for
serial communications
Stop Bits 1 or 2 Selects the number of stop
bits for the data word
Communications
Option Setup
-
(Documentation included with
Communications Option
equipment)